Capacitive level sensors von Vega Grieshaber KG [Page 1]   Capacitive level sensors von Vega Grieshaber KG [Page 5]   Page 5 of 18   Capacitive level sensors von Vega Grieshaber KG [Page 5]   Capacitive level sensors von Vega Grieshaber KG [Page 18]

Text from page 5 of catalogue Capacitive level sensors

Page 5 of catalogue Capacitive level sensors of Vega Grieshaber KG

VEGACAL 62

Approval XX without .................................................................................................................................................................. XM Ship approval ...................................................................................................................................................... CX ATEX II 1G, 1/2G, 2G EEx ia IIC T6 .................................................................................................................. CA ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG .................................................................................................... CM ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + Ship approval ..................................................................................... CK ATEX II 1G,1/2G,2G EEx ia IIC T6+ATEX II 1/2D,2D IP6X T 1) ...................................................................... DX ATEX II 1/2G, 2G EEx d ia IIC T6 2) .................................................................................................................... GX ATEX II 1/2D, 2D IP6X T 1) .................................................................................................................................. Version / Process temperature A Standard / -50 ... 150°C ............................................................................................................................... B Standard / -50 ... 200°C ............................................................................................................................... C with screening tube 316L / -50 ... 150°C 3) ............................................................................................... D with screening tube 316L / -50 ... 200°C 3) ............................................................................................... Process fitting / Material GA Thread G¾A PN64 / 316L .................................................................................................................. GC Thread G1A PN64 / 316L ................................................................................................................... GD Thread G1½ PN64 / 316L .................................................................................................................. GS Thread G1½A PN64 / Steel ................................................................................................................ Electronics H 4...20mA/HART® ............................................................................................................................ X for connection to a signal conditioning instrument ................................................................. P Profibus PA ..................................................................................................................................... F Foundation Fieldbus ..................................................................................................................... Housing / Protection K Plastic / IP66/IP67 ................................................................................................................... A Aluminium / IP66/IP68 (0.2 bar) ............................................................................................ D Aluminium double chamber / IP66/IP68 (0.2 bar) ............................................................. 8 StSt (electropolished) 316L / IP66/IP68 (0.2bar) ............................................................... Cable entry / Plug connection M M20x1.5 / without ............................................................................................................... N ½NPT / without .................................................................................................................. Indicating/adjustment module (PLICSCOM) X Without .......................................................................................................................... A Top mounted ................................................................................................................ Additional equipment X Without .................................................................................................................... CL62.
1) 2) 3)

Not in conjunct. with Housing / Protection "K" as well as "8" Only in conjunction with Housing / Protection "D" Not in conjuction with Process fitting / Material "GA", "GS"

Length in mm (from seal surface) 316L (100-6000 mm) per 100 mm Length screening tube in mm 316L (50-5960 mm) per 100 mm Insulation length in mm PTFE insulated (50-5990 mm) per 100 mm

• Further process fittings and options on request Level measurement – Capacitive AL-EN - 71

Catalogue Page 5 of catalogue Capacitive level sensors, Vega Grieshaber KG

Capacitive level sensors von Vega Grieshaber KG [Page 1]   Capacitive level sensors von Vega Grieshaber KG [Page 5]   Page 5 of 18   Capacitive level sensors von Vega Grieshaber KG [Page 5]   Capacitive level sensors von Vega Grieshaber KG [Page 18]
A choice of products and services from the Vega Grieshaber KG delivery programme: Radar level sensors   Capacitive level sensors   Vibration sensors  ... You will find information about the complete product range in the Vega Grieshaber KG catalogues.
Vega Grieshaber KG
» Inquire now!

Flash Catalogue