Text from page 21 of catalogue Bus, identification and control systems
Page 21 of catalogue Bus, identification and control systems of ifm Electronic GmbH
Notes and explanationsCore colours Yellow AS-i cable: A+ AS-i plus pole brown A– AS-i minus pole blue Black auxiliary voltage cable: E+ 24 V plus pole brown E– 24 V minus pole blue In the control cabinet the yellow AS-i cable should be laid uninterrupted to the AS-i power supply. The master is connected in parallel (blue = AS-i–, brown = AS-i+). If further input / output modules are to be used in the control cabinet, separate wiring (spurs) is recommended, starting from the AS-i power supply. Caution: The AS-i minus or plus poles must not be connected to ground at any point. Only the shield / GND connection at the AS-i power supply must be grounded! Input and output potentials have reference to the related AS-i module. Mixing reference potentials over several modules is not allowed.
!
Visit our website: www.ifm-electronic.com
21
Technical information and customer service
Accessories
Step 4: Configure the master automatically. After all slaves are correctly connected and addressed, the last step is carried out. The master must be informed which slaves must be present for a system to operate (list of the projected slaves LPS). This is done by the automatic configuration (for the plc master for example by pressing a button, for ifm controllers conveniently via the menu). In this process the AS-i master briefly passes to the projection mode, reads the current projection of all connected slaves and saves it permanently. Projection mode = master communicates with all slaves, e.g. during commissioning. Missing slaves are not indicated. Normal operating mode = master only communicates with slaves from the LPS. Missing slaves are indicated. Finished – that’s all!
Connection technology
AS-i Sensors, Pneumatic and actuator solutions
Safety at Work
I/O modules for field applications
I/O modules for Control cabinets
Power supplies and earth fault monitors
Controllers / Gateways, network extension
List of articles
General information
Special care must be taken to place the cable into the carriages for the lower parts to ensure a good contact. The carriages have the same colour code as the flat cable (yellow = AS-i, black = 24 V DC).

A choice of products and services from the ifm Electronic GmbH delivery programme:
Temperature sensors
Laser sensor
Level sensors
...
You will find information about the complete product range in the
ifm Electronic GmbH catalogues.
![Bus, identification and control systems von ifm Electronic GmbH [Page 1]](http://www.industryarea.de/img/zurueck_anfang.png)
![Bus, identification and control systems von ifm Electronic GmbH [Page 21]](http://www.industryarea.de/img/zurueck.png)
![Bus, identification and control systems von ifm Electronic GmbH [Page 21]](http://www.industryarea.de/img/vor.png)
![Bus, identification and control systems von ifm Electronic GmbH [Page 282]](http://www.industryarea.de/img/vor_ende.png)

Flash Catalogue









![Industriebedarf [deutsch]](http://www.industryarea.de/studentsadmin/images/de13.gif)
![Industrial Products [english]](http://www.industryarea.de/studentsadmin/images/en13w.gif)
![Productos industriales [español]](http://www.industryarea.de/studentsadmin/images/es13.gif)
![Produits industriels [français]](http://www.industryarea.de/studentsadmin/images/fr13.gif)
![???????????? ????????? [???????]](http://www.industryarea.de/studentsadmin/images/ru13.gif)
![???? [??]](http://www.industryarea.de/studentsadmin/images/cn13.gif)