Bus, identification and control systems von ifm Electronic GmbH [Page 1]   Bus, identification and control systems von ifm Electronic GmbH [Page 21]   Page 21 of 282   Bus, identification and control systems von ifm Electronic GmbH [Page 21]   Bus, identification and control systems von ifm Electronic GmbH [Page 282]

Text from page 21 of catalogue Bus, identification and control systems

Page 21 of catalogue Bus, identification and control systems of ifm Electronic GmbH

Notes and explanations

Core colours Yellow AS-i cable: A+ AS-i plus pole brown A– AS-i minus pole blue Black auxiliary voltage cable: E+ 24 V plus pole brown E– 24 V minus pole blue In the control cabinet the yellow AS-i cable should be laid uninterrupted to the AS-i power supply. The master is connected in parallel (blue = AS-i–, brown = AS-i+). If further input / output modules are to be used in the control cabinet, separate wiring (spurs) is recommended, starting from the AS-i power supply. Caution: The AS-i minus or plus poles must not be connected to ground at any point. Only the shield / GND connection at the AS-i power supply must be grounded! Input and output potentials have reference to the related AS-i module. Mixing reference potentials over several modules is not allowed.

!

Visit our website: www.ifm-electronic.com

21

Technical information and customer service

Accessories

Step 4: Configure the master automatically. After all slaves are correctly connected and addressed, the last step is carried out. The master must be informed which slaves must be present for a system to operate (list of the projected slaves LPS). This is done by the automatic configuration (for the plc master for example by pressing a button, for ifm controllers conveniently via the menu). In this process the AS-i master briefly passes to the projection mode, reads the current projection of all connected slaves and saves it permanently. Projection mode = master communicates with all slaves, e.g. during commissioning. Missing slaves are not indicated. Normal operating mode = master only communicates with slaves from the LPS. Missing slaves are indicated. Finished – that’s all!

Connection technology

AS-i Sensors, Pneumatic and actuator solutions

Safety at Work

I/O modules for field applications

I/O modules for Control cabinets

Power supplies and earth fault monitors

Controllers / Gateways, network extension

List of articles

General information

Special care must be taken to place the cable into the carriages for the lower parts to ensure a good contact. The carriages have the same colour code as the flat cable (yellow = AS-i, black = 24 V DC).

Catalogue Page 21 of catalogue Bus, identification and control systems, ifm Electronic GmbH

Bus, identification and control systems von ifm Electronic GmbH [Page 1]   Bus, identification and control systems von ifm Electronic GmbH [Page 21]   Page 21 of 282   Bus, identification and control systems von ifm Electronic GmbH [Page 21]   Bus, identification and control systems von ifm Electronic GmbH [Page 282]
A choice of products and services from the ifm Electronic GmbH delivery programme: Temperature sensors   Laser sensor   Level sensors  ... You will find information about the complete product range in the ifm Electronic GmbH catalogues.
ifm Electronic GmbH
» Inquire now!

Flash Catalogue